Fig. 1. Epithelial Na+ channel (ENaC) currents revealed by single
channel recording from cultured M1 cells. (A) In a cell-attached recording,
inward currents were recorded when the pipette voltage
(Vp) was held at +20 mV and +40 mV. (B) In an inside-out
recording, the single channel currents were detected when the pipette voltage
was held at +100 mV and +60 mV. (C) In an outside-out recording, the currents
were monitored when the pipette voltage was held at –60 mV. Bath
application of 5 µmol l–1 amiloride almost abolished the
ENaC currents. The currents were reversed when amiloride was washed off. c
indicates the closing level.