spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    

This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lieber, R. L.
Right arrow Articles by Friden, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lieber, R. L.
Right arrow Articles by Friden, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Journal of Experimental Biology, Vol 200, Issue 1 19-25, Copyright © 1997 by Company of Biologists


JOURNAL ARTICLES

Intraoperative sarcomere length measurements reveal differential design of human wrist extensor muscles

RL Lieber, BO Ljung and J Friden
Department of Orthopaedics, University of California, San Diego, USA. rlieber@ucsd.edu

The design of the wrist extensor muscles was studied using a combination of intraoperative laser diffraction and biomechanical modelling of data obtained from human patients and previously published data. Intraoperatively, the change in sarcomere length per degree joint angle rotation (i.e. dSL/d omega) was measured as the wrist was moved from neutral to full flexion in both the extensor carpi radialis brevis (ECRB) and extensor carpi radialis longus (ECRL) muscles. Sarcomere length change per degree rotation was approximately twice as great for the ECRB compared with the ECRL muscle (9.06 +/- 1.06 versus 4.69 +/- 1.20 nm degree-1, mean +/- S.E.M., N = 7). Muscle fibre length and wrist extensor moment arms were obtained from published data and dSL/d omega calculated. The experimental values for dSL/d omega were extremely close to the calculated values. These data demonstrate that architectural differences between the ECRB and ECRL are accentuated by differences between their wrist extensor moment arms. This differential design may permit the extensor muscles, as a group, to generate high force over a wider range of velocities than would be possible with a single muscle or it may permit conservation of mass such that the two muscles together can generate approximately the same force and excursion as a single muscle but with approximately 30% less mass.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
J. Exp. Biol.Home page
C. M. Eng, S. R. Ward, C. J. Vinyard, and A. B. Taylor
The morphology of the masticatory apparatus facilitates muscle force production at wide jaw gapes in tree-gouging common marmosets (Callithrix jacchus)
J. Exp. Biol., December 15, 2009; 212(24): 4040 - 4055.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
P. G De Deyne
Application of Passive Stretch and Its Implications for Muscle Fibers
Physical Therapy, February 1, 2001; 81(2): 819 - 827.
[Abstract] [Full Text] [PDF]




© The Company of Biologists Ltd 1997