spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    

This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wolf, T.
Right arrow Articles by Feltham, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wolf, T.
Right arrow Articles by Feltham, M.

Journal of Experimental Biology, Vol 199, Issue 4 959-972, Copyright © 1996 by Company of Biologists


JOURNAL ARTICLES

Validation of the doubly labelled water technique for bumblebees Bombus terrestris (L.)

T Wolf, C Ellington, S Davis and M Feltham

The doubly labelled water (DLW) technique was validated for the bumblebee Bombus terrestris (L.) using respirometry (RESP) from tethered roundabout flights. We injected small volumes (1 µl) of a mixture containing low concentrations of deuterium and 18O and withdrew 1-2 µl of haemolymph to determine initial 18O concentration. The injected isotopes were equilibrated with the body water pool after 10 min, and high material turnover allowed the analysis of final blood isotope concentrations after 5-7 h. On average (n=16), values measured using the DLW technique exceeded values measured using RESP by 3.1±9.9 %, a difference that was not statistically significant at the 99 % confidence level. The absolute error was 7.4±7.1 % (mean ± s.d.). Isotope dilution spaces of both deuterium and 18O were almost identical with the body water pool. We corrected for isotope fractionation, using a slightly higher value than usual for one of the fractionation factors. The single most important variable to influence DLW results, which could not be measured with the desired accuracy, was the volume of the final body water pool N. An overestimate of final N possibly resulted in the DLW overestimate.


This article has been cited by other articles:


Home page
J. Exp. Biol.Home page
J. F. Staples, E. L. Koen, and T. M. Laverty
`Futile cycle' enzymes in the flight muscles of North American bumblebees
J. Exp. Biol., February 15, 2004; 207(5): 749 - 754.
[Abstract] [Full Text] [PDF]


Home page
J. Exp. Biol.Home page
Y. Komai
Direct measurement of oxygen partial pressure in a flying bumblebee
J. Exp. Biol., January 9, 2001; 204(17): 2999 - 3007.
[Abstract] [Full Text] [PDF]


Home page
J. Exp. Biol.Home page
S. Roberts and J. Harrison
Mechanisms of thermal stability during flight in the honeybee apis mellifera
J. Exp. Biol., January 6, 1999; 202(11): 1523 - 1533.
[Abstract] [PDF]




© The Company of Biologists Ltd 1996