spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by SHADWICK, R. E.
Right arrow Articles by MILSON, W. K.
Right arrow Search for Related Content
PubMed
Right arrow Articles by SHADWICK, R. E.
Right arrow Articles by MILSON, W. K.
Journal of Experimental Biology 130,87-106 (1987)
Published by Company of Biologists 1987


Arterial Haemodynamics in the Cephalopod Mollusc, Octopus Dofleini

ROBERT E. SHADWICK 1, JOHN M. GOSLINE 2, and WILLIAM K. MILSON 2

1 Department of Zoology, University of British Columbia, Vancouver, BC Canada; Department of Biology, University of Calgary, Calgary, Alberta, Canada T2N 1N4
2 Department of Zoology, University of British Columbia, Vancouver, BC Canada

Simultaneous measurements of blood pressure and blood flow were made in the dorsal aorta of the cephalopod Octopus dofleini Wülker. In resting animals the heart rate varied from 8.5 to 14 beats min-1, while aortic pressure typically ranged from about 2.5 kPa at end diastole to 5.5 kPa at peak systole. Blood flow rate varied with pressure, averaging 0.9 ml s-1, with peak flow rates of 1.4–2.8 ml s-1. A slow asymptotic decline in both pressure and flow during the 2- to 4-s diastolic period indicated that the aorta functions as an elastic reservoir, as previously predicted. Aortic impedance spectra were derived from digitized pressure and flow data. The impedance amplitude decreased continuously with increasing frequency, while the impedance phase was always negative. These results are consistent with a two-element Windkessel model of the arterial system. The apparent pressure wave velocity, determined from transit times of pressure pulses in vivo, was > 10 m s-1. This was much higher than the intrinsic wave velocity we predicted from in vitro measurements of aortic elasticity. This anomaly occurred because the length of the aorta represented less than 1 % of the wavelength of the fundamental pulse frequency, due to the low heart rate in this species. Consequently, arterial haemodynamics in O. dofleini are dominated by strong wave reflections, but do not exhibit other wave propagation effects which are typical of mammalian circulatory systems. Thus, the simple Windkessel model adequately describes the arterial circulation of this species of cephalopod.

Key words: octopus, haemodynamics, vascular impedance, pressure wave velocity, Windkessel

Accepted on March 24, 1987







© The Company of Biologists Ltd 1987