Fig. 4. The radiated power of the miniature transmitter as measured in different configurations (circles = mean, boxes = S.E.M., whiskers = S.D.). When attached to a dummy body of 12 g, the effective radiated power of the transmitters improved. If the harness was attached to the transmitter (harness 1) the gain in ERP was significantly smaller compared to the version with the harness attached to the battery. (harness 2; paired samples t6=7.88, P<0.001).